The PD6870 is an FM Approved, CSA Certified and ATEX and IECEx Certified explosion-proof loop-powered indicator that is easy to install and program.
It can be seen from considerable distance and even in bright sunlight.
The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area. The meter gets all of the power it needs from the 4-20 mA loop and its 1 V drop results in a minimal burden on the loop.
The meter features a wide -40 to +75°C operating temperature range and comes with two ¾" NPT threaded conduit openings and flanges for wall or pipe mounting.
Calibration is a quick two-step process involving the adjustment of only high and low, non-interacting potentiometers.
Features- Explosion-Proof / Flame-Proof Loop-Powered Process Meter
- 4-20 mA Input
- 1.0" (25.4 mm) 3½ Digits LCD Display; -1999 to 1999
- 1 Volt Drop (4 Volt Drop with Backlight)
- HART® Protocol Transparent
- Loop-Powered Backlight Option
- Operates from -40 to 75°C (-40 to 167°F)
- Coarse and Fine Zero & Span Potentiometer Adjustments for Easy Field Scaling
- Flanges for Wall or Pipe Mounting
- Explosion-Proof, IP68, NEMA 4X Die-Cast Aluminum Enclosure
- FM Approved as Explosion-Proof / Dust-Ignition Proof / Flame-Proof
- CSA Certified as Explosion-Proof / Dust-Ignition Proof
- ATEX and IECEx Certified as Flame-Proof
- Conformal Coated PCBs for Dust and Humidity Protection
- Two ¾" NPT Threaded Conduit Openings (One Plug Installed)
- Pipe Mounting Kits
- Stainless Steel Tag Available
Specifications
Accuracy
- ± 0.1%
Approvals & Certifications
- ATEX, II 2 GD. Ex D IIC T6 Gb. Ex Tb IIIC T85° C Db
- CSA Class I, Division 1, Groups B, C, D, Class II, Division 1, Groups E, F, G, Class III, Division 1, T6. Class I, Zone 1, Ex D IIC T6
- FM Class I, Division 1, Groups B, C, D, Class II, Division 1, Groups E, F, G, Class III, Division 1, T6. Class I, Zone 1, AEx D IIC T6 Gb. Zone 21, AEx Tb IIIC T85° C
- IEC Ex D IIC T6 Gb. Ex Tb IIIC T85° C Db
Conduit Connection
- 3/4" NPT
Display
- 1"
- 3-1/2-Digit LCD
Enclosure, Body Material
- Explosion-proof Die Cast Aluminum with Glass Window
Environmental Protection
- IP66
- IP68
- NEMA 4X
Humidity
- 0 to 90% Non-Condensing
Input
- 4-20 mA
Operating Temperature
- -40° to 75° C (-40° to 167° F)
Storage Temperature
- -40° to 75° C (-40° to 167° F)
Update Time
- 2.5 seconds
Voltage Drop
- 1 Vdc at 20 mA without Backlight
- 4 Vdc at 20 mA with Loop-Powered Backlight