SEM1633 Dual Alarm Unit

Brand: Status Instruments
Does not ship to Virginia, United States

The SEM1633 provides an accurate alarm / switching function when used with RTD or Slidewire sensors.

The flexible design allows for the use of any resistive sensor within the range of (10 to 10,500) Ohms.

This means that in the standard product Pt100, 500, 1000, Ni or Cu sensors as well as slide wire sensors up to 100 K, can be accommodated.

Other sensor characteristics or your own 22 point linearisation characteristic (for slidewire or linear resistance) can be downloaded into the product enabling you to adapt it exactly to your application.

Relay outputs are independently configured for action, set point and dead band. Six actions are provided, normal High/Low/Deviation and inverted High/Low/Deviation.

For ease of use, a high efficiency switch mode power supply is fitted as standard and does not require any adjustment between ac or dc applications. Operating voltages are (10 to 48) Vdc and (10 to 32) Vac.

Our USB interface is fitted for quick and easy configuration. Just connect a standard USB cable between the SEM1633 and your PC.

Using our free configuration software, your PC will automatically upload the existing configuration data and guide you through any changes you wish to make.

To further help save time, the SEM1633 does not need to be wired to a power supply during the configuration process, it is powered via the USB interface from your PC.
Features
  • Suitable For RTD or Slidewire Sensors
  • High, Low,Deviation and Invert Trip Actions
  • Trip Rating 250 V AC 1A ; 30 V DC 1A
  • Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
  • Input Filter, User Linearisation Functions
  • Simple USB Configuration Port

Specifications

Accuracy

  • 0.2° C (0.36° F) + 0.05 % of Reading - Sensors RTD
  • Slide Wire: 0.05 %

Ambient Temperature Range

  • 10° to 30° C (50° to 86° F)

Approvals & Certifications

  • CE BS EN 61326, BS EN 61010-1 Installation Category II Pollution Degree
  • IEC

Communication

  • Baud Rate: 19,200 bit/sec

Electrical Connectors

  • DIN 0.00618
  • DIN 43880

Electrical Contacts

  • Form C - Relay Contact

Electrical Rating

  • 1 A at 250 Vac RMS, 1 A at 30 Vdc Resistive Load

Environmental Protection

  • IP65

Humidity

  • 10 to 90 % Relative Humidity, Non-Condensing

Indication

  • Relay 1, 2 on - Red LED

Input

  • Maximum

Interface Connection

  • USB 2

Isolation

  • 3,750 Vac Relay 1 to Input, Relay 1 to Relay 2 - Galvanic

Materials of Construction

  • Polymide 6.6 Self Extinguishing

Mounting

  • DIN Rail Enclosure Offering Protection ≥ IP65

Operating Temperature

  • -30° to 70° C (-22° to 158° F)

Power

  • < 1 W Full Power

Resistance

  • Accuracy: 10 to 500 ohms ± 0.055 ohms
  • Accuracy: 2,500 to 10,500 ohms ± 10 ohms
  • Accuracy: 500 to 2,500 ohms ± 0.5 ohms
  • Full Range 10 to 10,500 ohms

Response Time

  • < 500 milliseconds to Reach 95 % of Final Value

RTD Type

  • Cu100
  • Cu1000
  • Cu53
  • Ni100
  • Ni1000
  • Ni120
  • Ni507.5
  • Ni604
  • Pt100
  • Pt1000
  • Pt500

Sensor, Probe Material

  • Copper
  • Nickel
  • Platinum
  • Silicon

Sensor, Probe Type

  • RTD

Storage Temperature

  • -30° to 70° C (-22° to 158° F)

Supply Voltage

  • 10-32 Vac Protected by Internal 500 mA Resettable Fuse
  • 10-48 Vdc

System Requirements

  • Windows® XP

Temperature Range

  • -200° to 850° C (-328° to 1,562° F)

Turn-On Time

  • < 3 seconds

Update Time

  • 1 Minute - Warm-Up
  • 300 milliseconds

show more