Price
Request a Quote
Stock
Out of Stock
Does not ship to WA, United States

  • Channels - Dual Channel

Specifications

Accuracy

  • (mA Output/2,000) or 5 µA whichever is greater, Drift 1 µA/°C
  • ± 0.1 % of Full Scale ± 0.5° C (± 0.9° F) (Plus Sensor Error) - for K, J, E, N, L, U, B, C, D, W, R, S Thermocouples
  • ± 0.2 % of Full Scale ± 0.5° C (± 0.9° F) (Plus Sensor Error) - for T Thermocouple
  • Cold Junction: ± 0.05° C/°C
  • Cold Junction: ± 0.2° C (± 0.36° F)

Ambient Temperature Range

  • Configuration Ambient: 10° to 30° C (50° to 86° F)

Approvals & Certifications

  • ATEX - CE II 1 GD Ex ia IIC T4 Ga Ex iaD 20 T135° C Da Tamb: -40° to 70° C (-40° to 158° F)
  • CE BS EN 61326
  • IEC Ex

Burn-Out

  • Downscale - 3.8 mA
  • Up Scale - 21.5 mA

Communication

  • Baud Rate: 1,200 bit/sec
  • USB 2.0

Current

  • 2-Wire 4-20 mA Current Loop

Electrical Connectors

  • Screw Terminals 2.5 mm, Max.

Environmental Protection

  • IP65

Humidity

  • 10 to 90 % Relative Humidity, Non-Condensing

Isolation

  • Input to Output 500 Vdc

Operating Temperature

  • -40° to 70° C (-40° to 158° F)

Output

  • 2-Wire 4-20 mA Current Loop

Output Load

  • Maximum

Power

  • < 1 W Full Power Per Channel

Power Supply Effect

  • Loop Effect: ± 0.2 µA/V

Response Time

  • 500 milliseconds
  • Start Up 5 seconds
  • Update 160 milliseconds

Sensor, Probe Type

  • Standard TC: C (W5) Thermocouple
  • Standard TC: D (W3) Thermocouple
  • Standard TC: E Thermocouple
  • Standard TC: G (W) Thermocouple
  • Standard TC: J Thermocouple
  • Standard TC: K Thermocouple
  • Standard TC: L Thermocouple
  • Standard TC: N Thermocouple
  • Standard TC: R Thermocouple
  • Standard TC: S Thermocouple
  • Standard TC: T Thermocouple
  • Standard TC: U Thermocouple

Storage Temperature

  • -50° to 70° C (-58° to 158° F)

Supply Voltage

  • Loop Supply: 10-30 Vdc Per Channel

System Requirements

  • Equipment: PC Running Windows® XP or Later
  • Equipment: USB Configurator

Temperature Range

  • Cold Junction: -40° to 85° C (-40° to 185° F)

Thermal Drift

  • Thermocouple Offset 0.1° C/°C
  • Thermocouple Offset: 0.05° C/°C of Span

Update Time

  • Warm-Up: 2 minutes

show more